Welcome to QET, where innovation meets precision in laboratory equipments! As a leading provider in the field, we take pride in offering cutting edge solutions to meet the diverse the needs of modern laboratories. Our commitment to excellence, reliability, and customer satisfaction sets us apart in the world of laboratory equipment trading.

Ultrasonic Thickness Gauges PCE-FD 20

PCE-FD 20 is a portable ultrasonic tester or ultrasonic thickness gauge with a large LCD screen that displays A-scan maps of ultrasonic signals as well as B-scan cross sections. Ideal for use in mechanical engineering, aerospace and metallurgical applications, this high-frequency ultrasound-based Ultrasonic Thickness Gauges uses a contact transducer (two different probes included; 45° and 90°) to measure material thickness and identify flaws and defects such as discontinuity in welds.

Operating frequency range

1 ... 10 MHz

Measure time interval range (scan duration)

6 ... 1000 microseconds (µs)

Sound velocity range

1000 ... 9999 m/s

Deviation of measurement of time intervals

Not exceed ± 0.025 µs

Max. deviation of amplitude of signals at receiver input in 0 ... 110 dB range

Not exceed ± 0.5 dB

Testing gain region

125 dB

Averaging over the quantity of starts

1 ... 16

Range of time-variable gain (TVG) / Number of control points TVG

40 dB / 15

Duration of excitation pulse to load

0 ... 0.5 µs

Amplitude of excitation pulse to 50 Ohm load, not less

100, 200, 300

Operating frequency range of receiver at -3 dB

1 ... 10 MHz

Deviation of amplitudes of input signals in 10 ... 100% range of screen height

Not more than 1 dB

Scanning

1 ... 1000 µs

Scanning delay

0 ... 2000 µs

Measurement range of time intervals

0 ... 1000 µs

Prism of probe delay

0 ... 15 µs

Automatic signaling of defects (AFS)

Dual-gate

Setting range of AFS gates

0 ... 2000 µs

Adjusting thresholds of AFS gates

0 ... 100%

Detection of signals (receiver)

Positive half-wave, radio mode

Dimensions of device (approx.)

80 x 162 x 35 mm / 3.14 x 6.37 x 1.37"

Dimensions display (approx.)

48 x 74 mm / 1.88 x 2.91"

Power supply

100 ... 250 V AC or 3 x 1.5 V AA batteries

Weight (approx.)

250 g / 0.55 lb (without batteries)

  • Operating frequency range: 1 ... 10 MHz
  • Measured time interval range: 6 ... 1000 microseconds (µs)
  • Sound velocity: 1000 ... 9999 m/s
  • Implements shadow, echo and mirror-shadow testing methods
  • Features a USB interface for downloading data to PC for detailed analysis
  • Lightweight
  • Battery or electric power
  • 1.5 m long probe cable